Air Conditioning System
Symptom
| Suspected Area
| See page
|
All functions of the A/C system do not operate
| IG power source circuit
|
Click here
|
Back-up power source circuit
|
Click here
|
Air conditioning control panel circuit
|
Click here
|
A/C amplifier
|
Click here
|
Air flow control: No blower operation
| Blower motor circuit
|
Click here
|
Air conditioning control panel circuit
|
Click here
|
A/C amplifier
|
Click here
|
Air flow control: No blower control
| Blower motor circuit
|
Click here
|
Air conditioning control panel circuit
|
Click here
|
A/C amplifier
|
Click here
|
Air flow control: Insufficient air flow
| Blower motor circuit
|
Click here
|
A/C amplifier
|
Click here
|
The blower motor operates by itself or the motor speed changes arbitrarily (Speed does not change in accordance with automatic or manual control settings)*1
| IG signal circuit
|
Click here
|
Solar ventilation ECU
|
Click here
|
Temperature control: No cool air comes out
| Refrigerant volume
|
Click here
|
Refrigerant pressure
|
Click here
|
Air conditioning pressure sensor circuit
|
Click here
|
Air mix damper control servo motor circuit
|
Click here
|
Evaporator temperature sensor circuit
|
Click here
|
Room temperature sensor circuit
|
Click here
|
Ambient temperature sensor circuit
|
Click here
|
Air conditioning control panel circuit
|
Click here
|
Expansion valve
|
Click here
|
CAN communication system
|
Click here
|
A/C amplifier
|
Click here
|
No. 2 engine wire
|
Click here
|
Compressor with motor assembly
|
Click here
|
Power management control ECU
|
Click here
|
Temperature control: No warm air comes out
| Air mix damper control servo motor circuit
|
Click here
|
Evaporator temperature sensor circuit
|
Click here
|
Room temperature sensor circuit
|
Click here
|
Ambient temperature sensor circuit
|
Click here
|
Air conditioning control panel circuit
|
Click here
|
PTC heater circuit*2
|
Click here
|
CAN communication system
|
Click here
|
Radiator unit sub-assembly
|
Click here
|
A/C amplifier
|
Click here
|
ECM
|
Click here
|
Temperature control: Output air is warmer or cooler than the set temperature or response is slow
| Refrigerant volume
|
Click here
|
Refrigerant pressure
|
Click here
|
Solar sensor circuit
|
Click here
|
Room temperature sensor circuit
|
Click here
|
Ambient temperature sensor circuit
|
Click here
|
Evaporator temperature sensor circuit
|
Click here
|
Air mix damper control servo motor circuit
|
Click here
|
Air inlet damper control servo motor circuit
|
Click here
|
PTC heater circuit*2
|
Click here
|
Air conditioning control panel circuit
|
Click here
|
Radiator unit sub-assembly
|
Click here
|
Expansion valve
|
Click here
|
CAN communication system
|
Click here
|
A/C amplifier
|
Click here
|
No. 2 engine wire
|
Click here
|
Compressor with motor assembly
|
Click here
|
ECM
|
Click here
|
Power management control ECU
|
Click here
|
Temperature control: No temperature control (only Max. cool or Max. warm)
| Air mix damper control servo motor circuit
|
Click here
|
Room temperature sensor circuit
|
Click here
|
Ambient temperature sensor circuit
|
Click here
|
Evaporator temperature sensor circuit
|
Click here
|
Solar sensor circuit
|
Click here
|
Air conditioning control panel circuit
|
Click here
|
A/C amplifier
|
Click here
|
No air inlet control
| Air inlet damper control servo motor circuit
|
Click here
|
Air conditioning control panel circuit
|
Click here
|
A/C amplifier
|
Click here
|
No air flow mode control
| Air outlet damper control servo motor circuit
|
Click here
|
Air conditioning control panel circuit
|
Click here
|
A/C amplifier
|
Click here
|
Heater performance is low (engine is stopped)*2
| PTC heater circuit
|
Click here
|
A/C amplifier
|
Click here
|
ECO MODE switch indicator does not come on (ECO MODE switch does not operate)
| ECO switch circuit
|
Click here
|
A/C amplifier
|
Click here
|
Pollen removal mode does not operate (A/C system is operating normally)
| Air inlet damper control servo motor circuit
|
Click here
|
Air outlet damper control servo motor circuit
|
Click here
|
Blower motor circuit
|
Click here
|
Air conditioning control panel circuit
|
Click here
|
A/C amplifier
|
Click here
|
Unable to control A/C with the steering pad switch
| Steering pad switch circuit
|
Click here
|
Air conditioning control panel circuit
|
Click here
|
A/C amplifier
|
Click here
|
Diagnostic trouble codes (DTCs) are not recorded. Set mode is cleared when power switch is off.
| Back-up power source circuit
|
Click here
|
A/C amplifier
|
Click here
|
Remote Air Conditioning System*3
Symptom
| Suspected Area
| See page
|
The remote air conditioning system does not operate when the remote A/C switch on the key (electrical transmitter) is pressed.
| Wireless door lock control system
|
Click here
|
Data List (FL Door Courtesy, FR Door Courtesy, RL Door Courtesy SW, RR Door Courtesy SW, Back Door Courtesy SW)
|
Click here
|
Data List (Hood Courtesy SW)
|
Click here
|
Data List (Start Switch1, Start Switch2)
|
Click here
|
Data List (IG SW, ACC SW)
|
Click here
|
Data List (FL Door Lock Pos, FR Door Lock Pos, RL-Door Lock Pos SW, RR-Door Lock Pos SW)
|
Click here
|
Theft deterrent system
|
Click here
|
Operation check (key (electrical transmitter))
|
Click here
|
Use simulation method to check
|
Click here
|
The remote air conditioning system does not operate even though a wireless door lock is performed when the remote A/C switch on the key (electrical transmitter) is pressed.
| Data List (FL Door Courtesy, FR Door Courtesy, RL Door Courtesy SW, RR Door Courtesy SW, Back Door Courtesy SW)
|
Click here
|
Data List (Hood Courtesy SW)
|
Click here
|
Data List (Start Switch1, Start Switch2)
|
Click here
|
Data List (IG SW, ACC SW)
|
Click here
|
Data List (Stop Light Switch)
|
Click here
|
Data List (Shift Position)
|
Click here
|
Theft deterrent system
|
Click here
|
Use simulation method to check
|
Click here
|
The remote air conditioning system stops operating shortly after the system starts.
| Operation check
|
Click here
|
Use simulation method to check
|
Click here
|
The remote air conditioning system starts operating by itself.
| Use simulation method to check
|
Click here
|
Operation check (activation control, stop control, key (electrical transmitter))
|
Click here
|
Certification ECU
| -
|
A/C amplifier
|
Click here
|
Power management control ECU
|
Click here
|
The remote air conditioning system cannot be stopped using the remote A/C switch on the key (electrical transmitter).
| Customize (Stop Pre A/C)
|
Click here
|
Operation check (stop control, key (electrical transmitter))
|
Click here
|
A/C amplifier
|
Click here
|
Power management control ECU
|
Click here
|
Certification ECU
| -
|